Gas furnace in a winter outage

A gas furnace still needs electricity: the blower that pushes warm air through the ducts, the inducer fan and the igniter. Without power the burner will not light. The blower is the big load. An older furnace with a standard (PSC) motor draws about 500 W, and the starting surge of the whole furnace can reach 1,000 to 2,000 W.

For a 12-hour night with the blower running 10 hours a day, plus the router, a phone and some lights, the setup uses about 2,750 Wh. After inverter loss that is a battery of about 3,240 Wh, with about 1,540 W of startup peak. A full day doubles it to about 6,390 Wh, more than any single station we track, so plan on extra batteries or recharging.

A newer furnace with a variable-speed (ECM) blower draws far less, around 100 to 150 W. Set the furnace line below to 150 W and a full day drops to about 2,270 Wh. The model and motor type are on the furnace's rating plate, inside the door.

How to connect a furnace to a power station

Sources

Furnace watts and startup: EcoFlow's furnace guide (300 to 600 W running, 1,000 to 2,000 W at startup, runs 20 to 30 minutes an hour in cold weather), and a field study of furnace blowers (PSC about 500 W, ECM about 100 W, Pigg, Home Energy).