OutageMatch / Method

How we calculate, and where the numbers come from

OutageMatch answers one question: which portable power stations can run the devices you pick for as long as your outage lasts. This page lists every formula and assumption behind the answer, so you can check it or disagree with it.

Who makes this

OutageMatch is an independent site: no manufacturer pays to be listed or ranked. It earns a commission from Amazon when you buy through a link, and that is its only income. Stations are ordered by how closely they fit your setup, never by commission.

The calculation

energy used = sum of (watts x hours each device runs during the outage) battery needed = energy used / 0.85 running load = watts of every checked device, all on at once startup peak = running load + the largest (startup watts - running watts) A station fits when: rated capacity (Wh) >= battery needed continuous output (W) >= running load surge output (W) >= startup peak

Devices that cycle around the clock (refrigerator, router, sump pump) are counted by their total hours on per day, spread over the whole outage. Devices used at set times (CPAP, lights, TV) are counted by their hours per day for each full day, plus up to that many hours in a partial day.

Every result has a "Show the math" link with these three checks worked out for that station.

Default values

These are starting points. Every one can be changed in the finder, and your own device's label is always better than our default.

ItemOur defaultWhy
Inverter efficiency0.85The factor most published sizing guides use. They range from 0.80 to 0.90.
Refrigerator150 W, 10 h/day, 1,200 W startup1,500 Wh a day. Manufacturer guides put home refrigerators between 0.9 and 2.2 kWh a day. The EnergyGuide label is more exact: kWh per year x 1,000 / 365.
CPAP60 W with heated humidifier, 40 W without, 8 hPublished figures run from about 10 W for a bare machine to 60 W or more with humidifier and heated hose.
Wi-Fi router15 W, 24 hGuides give 10 to 25 W.
LED lights10 W, 5 hOne or two bulbs. Raise it for a whole room.
Phone charging10 W, 2 hAbout 20 Wh, one to two full charges.
Laptop50 W, 4 hVirginia Cooperative Extension lists 50 W.
TV100 W, 3 hGuides give 80 to 150 W depending on size.
Sump pump800 W, 5 h/day, 2,000 W startupA 1/3 HP pump running 10 to 15 minutes an hour in a storm. In dry weather it runs far less.
Solar4 sun hours, 75% of panel ratingA station counts as solar-sustained only if one day of sun refills one day of use and the battery alone lasts the hours without sun.

Sources

What this does not account for

Medical devices: treat every figure here as an estimate. Test your equipment on the power station before an outage and follow your device maker's instructions.