OutageMatch / Scenarios

Chest freezer through a long outage

A chest freezer is one of the easiest loads to carry through a long outage. An ENERGY STAR chest freezer uses about 215 kWh a year, about 600 Wh a day. We count it as 150 W for 4 hours a day of compressor time. Over three days that is 1,800 Wh, a battery of about 2,120 Wh after inverter loss, with about 1,000 W of startup surge.

Upright freezers use more: about 395 kWh a year for an ENERGY STAR model, almost twice as much. Your freezer's yellow EnergyGuide label gives its own figure: kWh per year x 1,000 / 365 is its daily Wh. Change the watts or hours below to match.

How to make the battery last

Sources

Annual use: ENERGY STAR freezers. Running and startup watts: Anker's freezer guide (chest freezers 180 to 480 W running, 500 to 1,200 W at startup). Hold times: USDA.

Common outage setups, worked out